| Inspection |
|
| 1. |
Turn the ignition switch OFF.
|
| 2. |
Install the refrigerant recovery/recycling/charging system.
(Refer to Air Conditioning System - "Repair procedures")
|
| 3. |
Turn ON the ignition switch, put into operation the air conditioner.
|
| 4. |
Calculate the reference voltage of the Recovery/Recycle/Recharge machine
high pressure value using the formula below.
|
| 5. |
Measure the sensor output voltage between terminal "1" and "2".
|
| 6. |
If the reference voltage value and the sensor output voltage value are
close to each other, the air conditioner pressure transducer is normal.
|
| 7. |
If 0V is output or the reference voltage value and sensor output voltage
value are not close to each other, replace the air conditioner pressure
transducer.
|
| Diagnosis With GDS |
| 1. |
The heating, ventilation and air conditioning can be quickly diagnosed
failed parts with vehicle diagnostic system (GDS).
※ The diagnostic system (GDS) provides the following information.
(1) Self diagnosis : Checking the failure code (DTC) and display.
(2) Current data : Checking the system input/output data state.
(3) Actuation test : Checking the system operation condition.
(4) Additional function : Other controlling such as he system option
and zero point adjustment.
|
| 2. |
Select the 'Car model' and the system to be checked in order to check
the vehicle with the tester.
|
| 3. |
Select the 'Current data' menu to search the current state of the input
/ output data.
The input / output data for the sensors corresponding to the A/C Pressure
Transducer can be checked.
|
| Replacement |
| 1. |
Disconnect the negative (-) battery terminal.
|
| 2. |
Recover the refrigerant with a recovery / charging station.
|
| 3. |
Press the lock pin and separate the A/C pressure transducer connector
(A).
|
| 4. |
Remove the A/C pressure transducer (A).
|
| 5. |
To install, reverse the removal procedure.
|
Description The A/C Pressure Transducer (APT) converts the pressure value of high pressure line into voltage value after measuring it.
Description The evaporator temperature sensor will detect the evaporator core temperature and interrupt compressor relay power in order to prevent evaporator from freezing by excessive cooling.
Inspection 1. Measure the resistance between the terminals. 2. The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor) Replacement 1.