| Removal |
| 1. |
Disconnect the negative (-) battery terminal.
|
| 2. |
Remove the front view camera cover (A).
|
| 3. |
Separate the front view camera connector (A).
|
| 4. |
After passing the fixing point (B) of the coupler, remove the front
view camera (A).
|
| Installation |
| 1. |
Install in the reverse order of removal.
|
| 2. |
When if replacing the front view camera with a new one, perform the
"Variant Coding" procedure by using the Diagnostic Tools.
|
| 3. |
Perform the front view camera unit calibration.
(Refer to Repair procedures - "Service Point Target Auto Calibration
(SPTAC)")
|