| Replacement |
| 1. |
Remove the condenser.
|
| 2. |
Remove the cap (A) on the bottom of the condenser with a L wrench.
|
| 3. |
Remove the receiver-drier (A) from condenser using a long nose plier.
Check for crumbled receiver-drier and clogged bottom cap filter.
|
| 4. |
Apply air conditioning compressor oil along the O-rings and threads
of the new bottom cap.
|
| 5. |
Insert a new receiver-drier into the receiver drier tank. The receiver-drier
must be sealed in vacuum before it is exposed to air for use.
|
| 6. |
Install a new bottom cap to the condenser.
|
Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air.
Description The A/C Pressure Transducer (APT) converts the pressure value of high pressure line into voltage value after measuring it.
Inspection Operating Logic Test (Manual only) Inspect the PTC operation by confirmation logic as follows; 1. Entering (1) Set the Floor mode and maximum heating position. (2) Turn off the blower switch.