| Inspection |
| 1. |
Connect the battery voltage and check the blower motor rotation.
|
| 2. |
If the blower motor does not operate well, substitute with a known-good
blower motor and check for proper operation.
|
| 3. |
Replace the blower motor if it is proved that there is a problem with
it.
|
| Replacement |
| 1. |
Disconnect the negative (-) battery terminal.
|
| 2. |
Separate the blower motor connector (A), loosen the mounting screws
and remove the blower motor (B).
|
| 3. |
To install, reverse the removal procedure.
|
Replacement 1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery / recycling / charging station.
Description It is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor.
Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2.
Description The temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. The signal from the control unit adjusts the position of the temperature door by operating the temperature switch.