Hyundai Venue (QX): Blower / Blower Motor. Repair procedures

Inspection
1.
Connect the battery voltage and check the blower motor rotation.

Hyundai Venue. Blower Motor. Repair procedures

2.
If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.
3.
Replace the blower motor if it is proved that there is a problem with it.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Separate the blower motor connector (A), loosen the mounting screws and remove the blower motor (B).

Hyundai Venue. Blower Motor. Repair procedures

3.
To install, reverse the removal procedure.

    Replacement 1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery / recycling / charging station.

    Description It is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor.

    Other information:

    Hyundai Venue (QX) (2020-2026) Service Manual: Condenser. Repair procedures

    Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2.

    Hyundai Venue (QX) (2020-2026) Service Manual: Temperature Control Actuator. Description and operation

    Description The temperature control actuator is located at the heater unit. It regulates the temperature by the procedure as follows. The signal from the control unit adjusts the position of the temperature door by operating the temperature switch.

    Categories

     
    Copyright В© 2026 www.hvenueqx.com - 0.0131