| Component Location |

| 1. Blower unit assembly |
| Component Location |

| 1. Intake seal 2. Intake upper case 3. Intake actuator 4. Intake door 5. Intake lower case 6. Blower pad |
7. Blower upper case 8. Climate air filter 9. Power mosfet 10. Resistor 11. Blower lower case 12. Blower motor |
Replacement 1. Disconnect the negative (-) battery terminal. 2. Recover the refrigerant with a recovery / recycling / charging station.
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater unit assembly. (Refer to Heater - "Heater Unit") 3. Separate the evaporator temperature sensor connector (A), loosen the mounting screws and remove the eva
Inspection 1. Connect the battery voltage and check the blower motor rotation. 2. If the blower motor does not operate well, substitute with a known-good blower motor and check for proper operation.