| Description |
| • |
Battery voltage: 12.4V or above
|
| • |
Engine : Running
|
| • |
Ambient temperature and coolant temperature
|
|
Ambient Temperature |
Coolant Temperature |
PTC Operation |
|
Below -20°C (-4°F) |
Below 75°C (167°F) |
ON |
|
10°C (50°F) |
Below 65°C (149°F) |
ON |
|
12°C (53.6°F) or above |
- |
OFF |
|
- |
80°C (176°F) or above |
OFF |

Replacement 1. Remove the heater unit assembly. (Refer to Heater - "Heater Unit") 2.
Inspection Operating Logic Test (Manual only) Inspect the PTC operation by confirmation logic as follows; 1. Entering (1) Set the Floor mode and maximum heating position.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.
Inspection 1. Disconnect the negative (-) battery terminal. 2. Remove the front door trim. (Refer to Body - "Front door trim") 3. Disconnect the power door mirror connector from the harness 4.