Hyundai Venue (QX): Crankshaft Position Sensor (CKPS) / Repair procedures

Inspection
Wave Form
1.
Check signal waveform of CKPS and CMPS using a diagnostic tool.
Specification : Refer to "DTC Guide"
Coil Resistance
1.
Turn the ignition switch OFF.
2.
Disconnect the knock sensor connector.
3.
Measure resistance between the CKPS terminals 1 and 2.
4.
Check that the resistance is within the specification.
Specification : 774 - 946Ω [20°C (68°F)]
Removal
1.
Turn ignition switch OFF and disconnect the battery negative (-) terminal.
2.
Lift the vehicle.
3.
Disconnect the crankshaft position sensor connector (A).
4.
Remove the CKP sensor after removing the installation bolt (B).
Crankshaft position sensor installation bolt :
7.8 - 11.8 N.m (0.8 - 1.2 kgf.m, 5.8 - 8.7 lb-ft)

Hyundai Venue. Repair procedures

Installation
Hyundai Venue. Repair procedures   
•
Install the component with the specified torques.
•
Note that internal damage may occur when the component is dropped. In this case, use it after inspecting.
Hyundai Venue. Repair procedures   
•
Apply the engine oil to the O-ring.
•
Insert the sensor in the installation hole and be careful not to damage when installation.
Hyundai Venue. Repair procedures   
•
Be careful not to damage the sensor housing and the connector.
•
Be careful not to damage the O-ring.
1.
Install in the reverse order of removal.

    Circuit Diagram [M/T] [A/T] Harness Connector

    Description Camshaft Position Sensor (CMPS) is a hall sensor and detects the camshaft position by using a hall element. It is related with Crankshaft Position Sensor (CKPS) and detects the piston position of each cylinder which the CKPS can't detect.