| Specifications |
|
Item |
Specification |
|
|
Ultrasonic sensor |
Voltage rating |
DC 12 V |
|
Detecting range |
1.6 - 4.7 in. (40 - 120 cm) |
|
|
Operation voltage |
DC 9 - 16 V |
|
|
Operation current |
MAX 350 mA |
|
|
Operation temperature |
-40 - 185°F (-40 - 85°C) |
|
|
Operation frequency |
48 ± 5 KHz |
|
|
Number of sensors |
8 units |
|
Component Location 1. Integrated body control unit (IBU) 2. Parking distance warning-forward (PDW-F) sensor ※ PDW(parking distance warning unit) function is included in the IBU.
Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2.
Description The ambient temperature sensor is located at the front of the condenser and detects ambient air temperature. It is a negative type thermistor; resistance will increase with lower temperature, and decrease with higher temperature.