| Specifications |
|
Shape |
Items |
Specifications |
|
|
Control current (voltage) [mA] |
0 - 1100 |
|
Supply pressure [kpa (kgf/cm², psi)] |
1569.06 (16, 227.57) |
|
|
Control pressure [kpa (kgf/cm², psi)] |
0 - 1569.06 (0 - 16, 0 - 227.57) |
|
| Internal
resistance(Ω) |
5.0 - 5.6 |
Description • 26 brake control solenoid valve(26/B_VFS) is attached to the valve body. • This variable force solenoid valve directly controls the hydraulic pressure inside the 26Brake.
Component Location (1)_Valve Body Cover 1. Valve Body Cover 3. Solenoid Valve Connector 2. Valve Body Cover Gasket Component Location (2)_Solenoid Valve 1.
Component Location 1. Heater unit assembly Compoents 1. Mode control actuator 2. Heater core case 3. Center duct seal 4. PTC heater 5. Heater core assembly 6. Heater case [LH] 7.
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater unit assembly. (Refer to Heater - "Heater Unit") 3. Separate the evaporator temperature sensor connector (A), loosen the mounting screws and remove the eva