Hyundai Venue (QX): Crash Pad / Crash Pad Center Panel. Repair procedures

Replacement
Hyundai Venue. Crash Pad Center Panel. Repair procedures   
•
Put on gloves to prevent hand injuries.
•
When removing with a flat-tip screwdriver or remover, wrap protective tape around the tools to prevent damage to components.
•
Use a plastic panel removal tool to remove interior trim pieces without marring the surface.
•
Take care not to bend or scratch the trim and panels.
1.
Remove the cowl side trim.
(Refer to Interior Trim - "Cowl Side Trim")
2.
Remove the glover box.
(Refer to Crash Pad - "Glove Box")
3.
Remove the floor console assembly.
(Refer to Floor Console - "Floor Console Assembly")
4.
Remove the heater & A/C control unit.
(Refer to Heating, Ventilation and Air Conditioning - ""Heater & A/C Control Unit (FATC)")
5.
Remove the crash pad lower panel
(Refer to Crash Pad - "Crash Pad Lower Panel")
6.
Using a remover and remove the crash pad side cover [RH] (A).

Hyundai Venue. Crash Pad Center Panel. Repair procedures

7.
Loosen the mounting screws and remove the crash pad center panel (A).

Hyundai Venue. Crash Pad Center Panel. Repair procedures

8.
Press the lock pin and separate the start botton connector (A).

Hyundai Venue. Crash Pad Center Panel. Repair procedures

9.
To install, reverse removal procedure.
Hyundai Venue. Crash Pad Center Panel. Repair procedures   
•
Make sure the connector is connected properly.
•
Replace any damaged clips (or pin-type retainers).

    Component Location 1. Crash pad center panel

    Component Location 1. Main crash pad assembly

    Other information:

    Hyundai Venue (QX) (2020-2026) Service Manual: Compressor. Repair procedures

    Removal    Precautions for using the plastic pulley • Be careful not to place the pulley to downwards of the floor or table.

    Hyundai Venue (QX) (2020-2026) Service Manual: Temperature Control Actuator. Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the temperature control actuator connector. 3. Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.