| Warning Lamp Activation |
| 1. |
Active fault.
|
| 2. |
Normal or historical fault only exist.
|
| 3. |
When turning the ignition switch ON during variant coding (EOL) mode,
the airbag warning lamp is turned on and blinks at intervals of 1 second
till the coding is completed.
If the variant coding is completed normally, the airbag warning lamp
will turn on for 6 seconds, and then turned off. Otherwise the airbag
warning lamp continuously blinks at intervals of 1 second.
When there is active fault in airbag system or SRSCM internal fault,
the variant coding (EOL) cannot be completed. In this case, perform
the variant coding (EOL) procedure again after troubleshooting with
the GDS.
|
| 1. |
Loss of battery supply to the SRSCM : warning lamp turned on continuously.
|
| 2. |
Loss of internal operating voltage : warning lamp turned on continuously.
|
| 3. |
Loss of Microprocessor operation : warning lamp turned on continuously.
|
| 4. |
SRSCM not connected : warning lamp turned on continuously.
|
Precautions General Precautions Please read the following precautions carefully before performing the airbag system service. Observe the instructions described in this manual, or the airbags could accidentally deploy and cause damage or injuries.
Component Replacement After Deployment • Before doing any SRS repairs, use the GDS Pro to check for DTCs.
Inspection Operating Logic Test (Manual only) Inspect the PTC operation by confirmation logic as follows; 1. Entering (1) Set the Floor mode and maximum heating position. (2) Turn off the blower switch.
Diagnosis with Diagnostic tool 1. In the body electrical system, failure can be quickly diagnosed by using the vehicle diagnostic system (Diagnostic tool). The diagnostic system (Diagnostic tool) provides the following information.