Hyundai Venue (QX): Indicators And Gauges / Schematic diagrams

Circuit Diagram
16 Gray MONO TFT

Hyundai Venue. Schematic diagrams

Hyundai Venue. Schematic diagrams

Hyundai Venue. Schematic diagrams

COG Type Segment LCD

Hyundai Venue. Schematic diagrams

Hyundai Venue. Schematic diagrams

Hyundai Venue. Schematic diagrams

Hyundai Venue. Schematic diagrams

    Components Standard Supervision Connector Pin Information No Description No Description Connector A Connector B Connector A Connector B 1 Ground signal 3 - 21 Trip switch (-) Rear defogger relay ouput 2 Illumination (-) - 22 - - 3 Rheostat switch (Down) input - 23 Trip switch2 (+) - 4 Rheostat switch (Up) input - 24 Drive mode switch input (+) - 5 Detent output - 25 Drive mode switch input (-) 6 AT ('P' position) - 26 - 7 AT ('R' position) - 27 - 8 AT ('N' position) - 28 MT ('N' position) 9 AT ('D' position) - 29 B CAN (Low) 10 AT ('S' position) - 30 B CAN (High) 11 - - 31 Engine run state output 12 Vehicle speed output Key in switch (-) 32 C CAN (High) 13 Alternator input - 33 C CAN (Low) 14 Fuel sender input Rear defogger switch input 34 - 15 - - 35 - 16 Fuel sender input - 36 - 17 - Driver seat belt switch input 37 Ground signal 18 Airbag input Aisst seat belt switch input 38 - 19 Oil pressure switch input Aisst seat mat switch input 39 IGN (+) 20 - Ground 40 Battery (+)

    Description Cluster Variant Coding As we have more options (ESC, TPMS, SCC, etc.) in the car, the dashboard now have more information to display depending on the chosen options.

    Other information:

    Hyundai Venue (QX) (2020-2026) Service Manual: Ambient Temperature Sensor. Repair procedures

    Inspection 1. Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature. 1. Ambient Sensor (+) 2.

    Hyundai Venue (QX) (2020-2026) Service Manual: Mode Control Actuator. Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the mode control actuator connector. 3. Verify that the mode control actuator operates to the defrost mode when connecting 12V to terminal 3 and grounding terminal 4.