Troubleshooting Connector assembly status test 1. Remove the connector (A) and reinstall it. Test for changing position of each ignition coil A : Ignition coil w/ misfire code B : Ignition coil w/o misfire code • Do not move with spark plug at the same time (move the ignition coil only)
Removal 1. Disconnect the battery nagative terminal. 2. Remove the engine cover. 3.
Removal 1. Disconnect the negative (-) battery terminal. 2. Remove the glove box. (Refer to Body - "Glove Box Housing") 3. Remove the smart key unit (A) after loosening the nuts.
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the temperature control actuator connector. 3. Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.