| Specification |
|
item |
Specification |
|
|
Compressor |
Type |
DVE12N |
|
Oil type & Capacity |
PAG 30 120 ± 10cc (4.23 ± 0.34oz.) |
|
|
Displacement |
122 cc / rev |
|
|
Expansion valve |
Type |
Block type |
|
Refrigerant |
Type |
R - 134a |
|
Capacity |
470 ± 25g (16.6 ± 0.88oz) |
|
|
Item |
Specification |
|
|
Fresh and recirculation |
Operating method |
Actuator |
|
Blower |
Type |
Sirocco pan |
|
Speed step |
Auto + 8 speed (Automatic), 1 - 4 speed (Manual) |
|
|
Speed control |
Power mosfet (Automatic), Resistor (Manual) |
|
|
Air filter |
Type |
Particle filter |
|
Item |
Specification |
||
|
Heater |
Type |
Fin & Tube type |
|
|
Type |
Tube - Fin 1Way |
||
|
Mode operating method |
Actuator |
||
|
Temperature operating method |
Actuator |
||
|
Evaporator |
Temperature control type |
Evaporator temperature sensor |
|
|
Blower singular |
A/C Output OFF Temperature |
A/C Output ON Temperature |
|
|
Manual control |
0.5 °C (32.9 °F) |
1.5 °C (34.7 °F) |
|
|
Dual control |
0.5 °C (32.9 °F) |
1.5 °C (34.7 °F) |
|
|
Manufacturer |
DOOWON |
||
| Tightening Torques |
|
Items |
N.m |
kgf.m |
lb-ft |
|
Compressor |
20.0 - 32.95 |
2.04 - 3.36 |
14.75 - 24.30 |
|
Condenser - Discharge hose |
8.8 - 13.7 |
0.9 - 1.4 |
6.5 - 10.1 |
|
Condenser - Liquid tube |
|||
|
Compressor - Discharge hose |
21.6 - 32.4 |
2.2 - 3.3 |
15.9 - 23.9 |
|
Compressor - Suction hose |
|||
|
Expansion valve - Evaporator |
8.8 - 13.7 |
0.9 - 1.4 |
6.5 - 10.1 |
Troubleshooting Problem Symptoms Table Before replacing or repairing air conditioning components, first determine if the malfunction is due to the refrigerant charge, air flow or compressor.
Inspection 1. Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature. 1. Ambient Sensor (+) 2.
Inspection 1. Disconnect the negative (-) battery terminal. 2. Remove the front door trim. (Refer to Body - "Front door trim") 3. Disconnect the power door mirror connector from the harness 4.