| Inspection |
| 1. |
Disconnect the battery negative terminal.
|
| 2. |
Remove the fuse box cover.
|
| 3. |
Remove the starter relay (A).
|
| 4. |
Using an ohmmeter, check that there is continuity between each terminal.
|
|||||||||||||||
| 5. |
Apply 12V to terminal 85 and ground to terminal 86.
Check for continuity between terminals 30 and 87.
|
| 6. |
If there is no continuity, replace the starter relay.
|
| 7. |
Install the starter relay.
|
| 8. |
Install the fuse box cover.
|
Removal 1. Turn the ignition switch OFF and disconnect the battery negative (-) terminal. 2. Remove the air cleaner assembly.
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater unit assembly. (Refer to Heater - "Heater Unit") 3. Separate the evaporator temperature sensor connector (A), loosen the mounting screws and remove the eva
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the temperature control actuator connector. 3. Verify that the temperature control actuator operates to the cool position when connecting 12V to terminal 3 and grounding terminal 7.