| Description |
| • |
Transaxle oil temperature sensor monitors the automatic transaxle fluid's
temperature and conveys the readings to TCM.
|
| • |
It is an NTC (Negative Thermal Coefficient) sensor whose resistance
has an inversely proportional relationship with the temperature level.
|
| • |
Data produced by this sensor is used to identify damper clutch activation
and deactivation zones within the low temperature and high temperature
range and to compensate hydraulic pressure levels during gear changes.
|
Inspection â–¶ Transaxle Control Module(TCM) Problem Inspection Procedure 1. TEST TCM GROUND CIRCUIT: Measure resistance between TCM and chassis ground using the backside of TCM harness connector as TCM side check point.
Specifications ▷ Type : Negative Thermal Coefficient Type Temp.[(°C)°F] Resistance (Ω) Min Max (-40) -40 48153 45301 51006 (-20) -4.
Inspection Operating Logic Test (Manual only) Inspect the PTC operation by confirmation logic as follows; 1. Entering (1) Set the Floor mode and maximum heating position. (2) Turn off the blower switch.
Component Location 1. Blower unit assembly Component Location 1. Intake seal 2. Intake upper case 3. Intake actuator 4. Intake door 5. Intake lower case 6. Blower pad 7.