Hyundai Venue (QX): Smart Key System / Specifications

Specifications
Smart Key Unit (Integrated Body Contorl Unit(IBU))
Items
Specification
Rated voltage
DC 12V
Operating voltage
DC 9 - 16V
Operating temperature
-40°F to 185°F (-40°C to 85°C)
Load
Less than 3.9mA (Approx. 2.5mA increased with welcome light operation)

RF Receiver
Items
Specification
Frequency
433.92 Mhz
Antenna type
FSK (Frequency Shift Keying)

Smart Key Fob
Items
Specification
Battery
Lithium battery 3V 1EA
Distance
30m from vehicle, RF : 30m, Passive(LF) : 0.7m
Battery life
More than 2 years (10 times / a day)
Hyundai Venue. Specifications   
An inappropriately disposed battery can be harmful to the environment and human health.
Dispose the battery according to your local law(s) or regulation.
Push buttons
4 (Door Lock / Unlock, Remote start, Panic)
Frequency(Rx)
134.2 kHz
Frequency(Tx)
433.92 MHz
Numbers
2EA

Antenna
Items
Specification
Rated voltage
DC 12V
Operating voltage
DC 9 - 16V
Operating temperature
-22°F to 167°F (-30°C to 75°C)
Frequency
125kHz
Numbers
Interior(2EA), Door(2EA), Bumper(1EA)

    Component Location 1. Interior antenna 1 2. Interior antenna 2 3. Door outside handle antenna 4. Smart key unit 5.

    Other information:

    Hyundai Venue (QX) (2020-2026) Service Manual: PTC Heater. Repair procedures

    Inspection Operating Logic Test (Manual only) Inspect the PTC operation by confirmation logic as follows; 1. Entering (1) Set the Floor mode and maximum heating position. (2) Turn off the blower switch.

    Hyundai Venue (QX) (2020-2026) Service Manual: Temperature Control Actuator. Components and components location