Hyundai Venue (QX): Blower / Blower Resistor (Manual). Repair procedures

Inspection
1.
Measure the resistance between the terminals.
2.
The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor)

Hyundai Venue. Blower Resistor (Manual). Repair procedures

Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Separate the resistor connector (A), loosen the mounting screws and remove the blower resistor (B).

Hyundai Venue. Blower Resistor (Manual). Repair procedures

3.
To install, reverse the removal procedure.

    Description It is installed to the DATC and adjusts the fan rpm by precisely controlling the voltage applied to the blower motor.

    Description The climate control air filter is located in the blower unit. It eliminates foreign materials and odor. The particle filter performs a role as an odor filter as well as a conventional dust filter to ensure comfortable interior environment.

    Other information:

    Hyundai Venue (QX) (2020-2026) Service Manual: Compressor. Description and operation

    Description The compressor is the power unit of the A/C system. It is located on the side of engine block and driven by a V-belt of the engine. The compressor changes low pressure and low temperature refrigerant gas into high pressure and high temperature refrigerant gas.

    Hyundai Venue (QX) (2020-2026) Service Manual: Compressor. Repair procedures

    Removal    Precautions for using the plastic pulley • Be careful not to place the pulley to downwards of the floor or table.