| Inspection |
| 1. |
Check signal waveform of HO2S using a diagnostic tool.
|
| 1. |
Turn the ignition switch OFF.
|
| 2. |
Disconnect the knock sensor connector.
|
| 3. |
Measure resistance between HO2S heater terminals 3 and 4.
|
| 4. |
Check that the resistance is within the specification.
|
| Removal |
| 1. |
Turn the ignition switch OFF and disconnect the battery negative (-)
terminal.
|
| 2. |
Disconnect the connector (A), and then remove the sensor (B).
[Bank 1 / Sensor 1]
[Bank 1 / Sensor 2]
|
| Installation |
|
|
| 1. |
Install in the reverse order of removal.
|
Circuit Diagram [M/T] [A/T] Harness Connector [Bank 1 / Sensor 1] [Bank 1 / Sensor 2]
Description Accelerator Position Sensor (APS) is installed on the accelerator pedal module and detects the rotation angle of the accelerator pedal.
Description The photo sensor is located at the center of the defrost nozzles. The photo sensor contains a photovoltaic (sensitive to sunlight) diode. The solar radiation received by its light receiving portion, generates an electromotive force in proportion to the amount of radiation received which is transferred to th
Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the heater unit assembly. (Refer to Heater - "Heater Unit") 3. Separate the evaporator temperature sensor connector (A), loosen the mounting screws and remove the eva