| Specification |
|
Temperature [°C (°F)] |
Resistance (kΩ) |
|
-40 (-40) |
40.93 - 48.35 |
|
-30 (-22) |
23.43 - 27.34 |
|
-20 (-4) |
13.89 - 16.03 |
|
-10 (14) |
8.50 - 9.71 |
|
0 (32) |
5.38 - 6.09 |
|
10 (50) |
3.48 - 3.90 |
|
20 (68) |
2.31 - 2.57 |
|
25 (77) |
1.90 - 2.10 |
|
30 (86) |
1.56 - 1.74 |
|
40 (104) |
1.08 - 1.21 |
|
60 (140) |
0.54 - 0.62 |
|
80 (176) |
0.29 - 0.34 |

Description Intake Air Temperature Sensor (IATS) is included inside Manifold Absolute Pressure Sensor and detects the intake air temperature.
Singal Waveform
Inspection 1. Check the condenser fins for clogging and damage. If clogged, clean them with water, and blow them with compressed air. If bent, gently bend them using a screwdriver or pliers. 2.
Inspection 1. Check the resistance of the ambient temperature sensor between terminals 1 and 2 whether it changes by changing the ambient temperature. 1. Ambient Sensor (+) 2.