Hyundai Venue (QX): Hydraulic System / Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Hyundai Venue (QX) (2020-2025) Service Manual / Automatic Transaxle System\ / Hydraulic System / Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Specifications
â–· Control type : Normally low type
Shape
Items
Specifications

Hyundai Venue. Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Control current (voltage) [mA]
0 - 850
Supply pressure [kpa (kgf/cm², psi)]
539.36 (5.5, 78.23)
Control pressure [kpa (kgf/cm², psi)]
0-519.75 (0-5.3, 0-75.38)
 Internal resistance(Ω)
4.8 - 5.4

    Description • Torque converter control solenoid valve (T/CON_VFS) is attached to the valve body. • This variable force solenoid valve indirectly controls the hydraulic pressure inside the torque converter.

    Component Location (1)_Valve Body Cover 1. Valve Body Cover 2. Valve Body Cover Gasket 3. Solenoid Valve Connector Component Location (2)_Solenoid Valve 1.

    Other information:

    Hyundai Venue (QX) (2020-2025) Service Manual: Blower Unit. Components and components location

    Component Location 1. Blower unit assembly Component Location 1. Intake seal 2. Intake upper case 3. Intake actuator 4. Intake door 5. Intake lower case 6. Blower pad 7.

    Hyundai Venue (QX) (2020-2025) Service Manual: Blower Resistor (Manual). Repair procedures

    Inspection 1. Measure the resistance between the terminals. 2. The measured resistance is not within specification, the blower resistor must be replaced. (After removing the resistor) Replacement 1.