Hyundai Venue (QX): Hydraulic System / Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Hyundai Venue (QX) (2020-2026) Service Manual / Automatic Transaxle System\ / Hydraulic System / Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Specifications
â–· Control type : Normally low type
Shape
Items
Specifications

Hyundai Venue. Torque Converter Control Solenoid Valve (T/CON_VFS). Specifications

Control current (voltage) [mA]
0 - 850
Supply pressure [kpa (kgf/cm², psi)]
539.36 (5.5, 78.23)
Control pressure [kpa (kgf/cm², psi)]
0-519.75 (0-5.3, 0-75.38)
 Internal resistance(Ω)
4.8 - 5.4

    Description • Torque converter control solenoid valve (T/CON_VFS) is attached to the valve body. • This variable force solenoid valve indirectly controls the hydraulic pressure inside the torque converter.

    Component Location (1)_Valve Body Cover 1. Valve Body Cover 2. Valve Body Cover Gasket 3. Solenoid Valve Connector Component Location (2)_Solenoid Valve 1.

    Other information:

    Hyundai Venue (QX) (2020-2026) Service Manual: Intake Actuator. Repair procedures

    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the intake actuator connector. 3. Verify that the intake actuator operates to the fresh position when connecting 12V to terminal 3 and grounding terminal 4.

    Hyundai Venue (QX) (2020-2026) Service Manual: Heater & A/C Control Unit (DATC). Components and components location

    Categories

     